The engine will not start.
Starter does not turn the
engine.
If the starter motor works
with double turning, trouble
shoot the glow plug heating.
Check with LED
Trouble shoot according to page 125
Clean and lubricate with
copper paste
Change the fuse.
Localise the fault
Clean and lubricate with
copper paste
Check the cable connections
or replace the switch
Adjust the setting or replace
the cable harness with sensor
Bad contact on battery poles
or starter motor
Blown fuse FU8
Poor/no earth contact
Defective ignition lock
Parking brake sensor
defective. LED in sensor.
Sensor hydrostatic pedals
defective. LED in sensor.
Charge the battery
Change the battery
Control current starter motor open
circuit / short circuit
Replace the circuit board page 99
Check the connections.
Change the starter motor
Fill with fuel.
Fuel filter clogged
Tank ventilator blocked
Seal or replace cable
Oil pressure sensor or its
cable defective
Change filter, page 71.
Clean or replace the fuel cap
Replace the feed pump
Partial air in the suction line
tank - feed pump
Glow plug heating
malfunction
Feed pump does not work
Fuel hoses blocked or
constricted
Check the timing. Repair
the mechanical fault
Clean or replace the pipes
Injection pump internal fault.
Contact the diesel workshop.
Injection pump defective
No fuel to
the injection pump
Fuel tank empty.
Main fuse FU13 tripped
Faulty fuel supply
Indication panel
srtill working
Fuse FU3 tripped
Check / repair actuating pipe
The machine is dead
Starter motor and/or cable
connection defective
Operating current start motor
disruption / short-circuit
Discharged battery,
See inspection hole
page 37
Serious engine damage
Repair / Replace the engine
Adjust the setting or replace
the cable harness with sensor
Discharged battery
see inspection hole
Charge / replace the battery
Localise the fault
Fuse FU12 tripped
Change the fuse.
Localise the fault
Change the fuse.
Localise the fault
Change the fuse.
Localise the fault
Trouble shoot according to
page 125
Repair cable or replace the
circuit board
Check with LED
Measure the coil resistance
Set point 0.3
No voltage to
the injection pump
Zero feed arm
actuated (sabotage)
Theft protection activated
Main power relay clock
function
Trouble shoot according to
page 127

Table of Contents