The motor runs normally, low /no power
Troubleshoot as set out on
Trouble shoot according to
Trouble shoot according to
page 131
See Danfoss manual
Fill the oil to the right level.
Vent the system
Change the filter and oil
See Danfoss manual
Trouble shoot according to
page 131
Control wrongly adjusted or
damaged. Replace / adjust
Lubricate the brake links and
cables. Adjust
Repair or replace the
hydraulic pump
See Danfos manual
Electrical fault
Hydraulic fault
Pump working hydraulic
defective
Internal leakage in control
Solenoid valve defective
Inner leakage hydraulic pump
Fault on hydraulic motor
Filter clogged
Low oil level in the tank.
Air in the hydraulic system
Too low feed pressure
(18 bar)
Defective accelerator
Internal damage hydraulic
pump
Brake wrongly adjusted or
jamming
The parking brake is applied
Hydraulic transmission
Hydraulic transmission
Auxiliary system
No gear shift high speed / low
No drive to machine in either
direction
The machine is running
slowly, feels weak or has no
drive at all.
Hydraulic pump or motors must not be opened during the warranty period
Partial braking, see
P-brake still applied
The parking brake must be on
Check the lock
Replace the solenoid valve
Check the
hose installation
Hose crushed or connected
incorrectly.