EasyManua.ls Logo

Husqvarna PT26D - Page 142

Husqvarna PT26D
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Change linkage/adjust to right
setting
Replace the brake lining 80
Lubricate and adjust page 73
Repair or replace the
hydraulic pump
Replace the spring
See Danfoss manual
Spring broken / missing
Wrongly adjusted or jamming
Internal fault hydraulic pump
Worn out or soaked in oil
Damaged or wrongly adjusted
Brake linkage
Brake pad
Hydrostatic transmission
Accelerator
Weak parking brake
The machine drives even in
neutral free position
Transmission: Overheating, other indications
Overheated transmission
Poor air circulation
Cooling fan malfunction
Trouble shoot according to
page 126
Fill the oil to the right level
Oil level too low
Clean off contamination
Dirt, grass or leaves on the
radiator
Partial braking
Check and adjust the parking
brake
Coil valve defective
See Danfoss manual
Internal damage to the pump
or hydraulic motor
Replace the damaged unit.
Jerky start
Defective accelerator
Check, Repair, Lubricate
Jamming, Damage, Spring
failure
Fill the oil to the right level
Bleed the pump
Oil level too low / air
Low feed pressure
(hydraulic oil
Check (18 bar)
Jammed wire
Check / clean
pressure limiting valve
Lubricate / replace
Wrongly connected hoses to
the rear wheel circuit
See hydraulic diagram
page 161

Table of Contents

Other manuals for Husqvarna PT26D

Related product manuals