EasyManua.ls Logo

HUST CNC H6D-B3 - Axis Limit and System Errors

Default Icon
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HUST CNC H6D-B3 MANUAL
77
Check the program or revise the settings inParameter page 1for software travel
limit.
ERROR-22
Em-Stop, Home Again
Message: Controller is in emergency stop state.
Recommended Remedy:
Resolve the cause for emergency stop. Restore Emergency-STOP button and press
RESET.
ERROR-30.1
BATT.LOW
Message: The battery (BT1) for data storage is out of charge or service.
Recommended Remedy:
Replace the battery BT1or power on for 5 hours.
ERROR-31
None PLC
Message: There is no PLC ladder program in the memory.
Recommended Remedy:
Contact the engineer.
ERROR-51
Message:
The machine coordinate of X(L)-axis > The setting of software OT +.
Recommended Remedy:
Ascertain the value of Parameter page 1Software OT +1.
ERROR-52
Message:
The machine coordinate of X(L)-axis < The setting of software OT.
Recommended Remedy:
Ascertain the value of Parameter page 1Software OT1.