2.6
COOLANT “F2”:
• Press F2 continuously until desired COOLANT mode is selected. The pictogram will be changed to
yellow when selected.
• Coolant O󰀨 (White Background) - When selected no coolant will ow
• Coolant Manual - When selected Coolant will ow continuously
• Coolant Automatic - When selected Coolant will ow only when the blade is running OR when the
blade is running and the head is descending.
reset
PC
RUN
PROG
reset
QUEUE
reset
TCT
mm
inch
MIST OPTION “F4”:
• Press F4 continuously until desired MIST mode is selected. The pictogram will be changed to yellow
when selected.
• Mist O󰀨 (White Background) - When selected no coolant will ow
• Mist Manual & Automatic - Blade start must be selected for the MIST to operate
UNITS “F3”:
• This button is used to change the values between metric and imperial
RESET PC “F5”:
• This button is used to reset the number of pieces cut
RESET QUEUE “F1”:
• This button is used to reset the queue
RESET TCT “F4”:
• This button is used to reset the total time cut
RUN PROG “F5”:
• This button is used to program a sequence of jobs in Automatic Queue Mode