8 | Performing Maintenance HYDAC FILTER SYSTEMS GMBH
68 / 100 MoWa OLF-5 3433222d en-us print
10. Push the filter bowl with the filter element up into the
mount on the filter head.
11. Push the housing clamp (1) from the bottom over the fil-
ter bowl to the top over bead on the filter bowl/filter
head.
Tighten the housing clamp in clockwise direction using
an Allen wrench ( =5mm). The tightening torque is 5
Nm.
12. Check the drain plug on the filter bowl for a correct fit
with an Allen key ( =6mm).