1.2 Performance Description
Sampling rate: 1000 times per second.
Static measurement accuracy: 0.001mm.
Following range: 0-25mm.
The signal will not decay with strong capacity of resisting when the length
of signal transmission cable is up to 100m.
Support network communications and U disk online update.
Supports shake suppression function, can effectively suppress shaking
caused by blowing and scumming.
Adapt to any cutting head and nozzle.
Support alarm while hitting the board and beyond the edge.
Supports 1 point, 2 point and 16 point capacitance calibration, which
supports the display of the calibration curve.
Support capacitor real-time calibration, which can effectively solve the
influence of temperature and other factors on the capacitive sensor.
16-bit DA output, output voltage (±10V) signal in sensor control mode, or
linear height signal in the distance measurement mode output voltage (0-
10V), 1000 update cycles per second.
14-bit AD input, detecting external analog voltage signal (0V-10V) to adjust
the static distance in real time.
Support oscilloscope function to detect capacitance and height changing in
real time.
Support oscilloscope function, which can view AD/DA changes anytime.
Support EtherCAT bus communication. (optional)