EasyManua.ls Logo

Hypertherm Powermax125 - Machine Interface Pinout

Hypertherm Powermax125
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100 Powermax125 Operator Manual 808080 Revision 0
7 Mechanized Cutting
Machine interface pinout
Figure 2 – Connector sockets
Refer to Table 10 when connecting the power supply to a torch height controller or CNC controller with a machine
interface cable.
Table 10 – Machine interface cable signals
Signal Type Notes Connector sockets External cable wires
Start (start
plasma)
Input Normally open.
18 VDC open circuit voltage at
START terminals. Requires dry
contact closure to activate.
3, 4 Green, black
Transfer (start
machine motion)
Output Normally open. Dry contact closure
when the arc transfers.
120 VAC/1 A maximum at the
machine interface relay.
12, 14 Red, black
Ground Ground 13
Voltage divider Output Divided arc signal of 20:1, 21.1:1,
30:1, 40:1, 50:1 (provides a
maximum of 16 V).
5(-), 6(+) Black (-), white (+)
3
4
5
6
12
13
14

Table of Contents