30 Powermax125 Operator Manual 808080 Revision 0
2 Power Supply Setup
Power connection for the Powermax125
Powermax125 3-phase systems are available in the following fixed-voltage configurations:
480 V CSA
600 V CSA
400 V CE
380 V CCC
The Hypertherm rated output is 30 125 A, 175 VDC.
Table 4 480 V CSA
Table5 600V CSA
Table6 400V CE
Input voltage (V) 480
Input current (A) at rated output (21.9 kW) 31
Input current (A) at arc stretch 50
Fuse, slow-blow (A) 50
Input voltage (V) 600
Input current (A) at rated output (21.9 kW) 24
Input current (A) at arc stretch 38
Fuse, slow-blow (A) 40
Input voltage (V) 400
Input current (A) at rated output (21.9 kW) 36
Input current (A) at arc stretch 55
Fuse, slow-blow (A) 60