Install and Set Up the Plasma Power Supply
2
Powermax65/85/105 SYNC Operator Manual 810470 43
Powermax85 SYNC
CSA configurations (1-phase)
CSA configurations (3-phase)
CE/CCC configurations (3-phase)
Input voltage at 50 Hz/60 Hz* 200 V – 208 V 230 V – 240 V 480 V
Input current at rated output (85 A × 143 VDC = 12.2 kW) 70 A / 68 A 58 A 29 A
Input current during arc stretch 98 A 98 A 50 A
Fuse (time-delay) 100 A 100 A 50 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz* 200 V – 208 V 230 V – 240 V 400 V 480 V 600 V
Input current at rated output
(85 A × 143 VDC = 12.2 kW)
42 A / 40 A 35 A 21 A 18 A 17 A
Input current during arc stretch 60 A 60 A 38 A 31 A 30 A
Fuse (time-delay) 60 A 60 A 40 A 30 A 30 A
* All models have a voltage tolerance of +10% / -15%.
Input voltage at 50 Hz/60 Hz* 380 V 400 V
Input current at rated output (85 A × 143 VDC = 12.2 kW) 20.5 A 19.5 A
Input current during arc stretch 38 A 38 A
Fuse (time-delay) 40 A 40 A
* All models have a voltage tolerance of +10% / -15%.