015 (continued)
DID YOU RECEIVE THE CORRECT AUDIO RESPONSES?
Yes No
016
Check the power supply (see “Power Supply” on page 2-26).
If the power supply voltages are correct, replace the monitor.
If the symptom remains, replace any optional video memory
modules installed on the system board and retest the system. If the
symptom remains, replace the system board.
017
Do not power off the system unit to perform this step.
Unplug the monitor I/O signal cable from the system unit.
Refer to the following figure, and measure the monitor connector voltages
at the rear of the system unit, performing steps 1 through 4 sequentially.
1
5
11
15
6
10
Figure 2-10. Monitor Connector
(Step 017 continues)
1. Press 7; then press Enter and check for:
0 to +0.2 V dc from pin 13 to 10 (ground)
0 to +0.2 V dc from pin 14 to 10 (ground)
2. Press Enter; then check for:
+3.5 to +4.5 V dc from pin 13 to 10 (ground)
0 to +0.2 V dc from pin 14 to 10 (ground)
3. Press Enter; then check for:
0 to +0.2 V dc from pin 13 to 10 (ground)
0 to +0.2 V dc from pin 14 to 10 (ground)
4. Press Enter; then check for:
+0.5 to 1.0 V dc from pin 13 to 10 (ground)
+3.5 to 4.5 V dc from pin 14 to 10 (ground)