Mouse
Note: A sticking keybutton can cause the mouse to operate incorrectly. If
you suspect this, go to “Keyboard” on page 2-32.
001
Power off the system unit.
Make sure the mouse ball turns freely.
Insert the Advanced Diagnostics diskette into drive A.
Power on the system unit.
Make a note of any error messages, then press Esc.
Press 0 (SYSTEM CHECKOUT), then press Enter.
Press Y, then press Enter.
Press 0 (RUN TESTS ONE TIME), then press Enter.
Run the Mouse tests.
Follow the instructions on the screen.
DO THE MOUSE DIAGNOSTIC TESTS RUN WITHOUT ERRORS?
Yes No
002
If you receive any error
except
an 8613 error replace the mouse.
If you receive an 8613 error, replace the system board.
003
The system unit is operating normally.
If the symptom remains, replace the mouse.