Press the Enter key.
__ 46. Add the number of the ASP you want to add the disk unit to. The system
ASP is ASP 1.
Press the Enter key.
__ 47. The Confirm Add Units display appears showing the configuration your
system will have when the add completes.
Note: If you have selected the wrong ASP, press F12 to change your
options.
Press the Enter key to continue. The add process will take several minutes
to complete.
__ 48. Install the disk unit shield cover .
__ 49. Install the system unit front cover.
__ 50. If you have a printer, print the configuration list. A service representative
may refer to the configuration list in the future.
a. On the AS/400 Main menu command line type:
Note: You need to be signed on with service authority.
STRSST
Press the Enter key.
b. On the STRSST display, select Start a service tool option.
Press the Enter key.
c. On the Start a Service Tool display, select Hardware service manager
option.
Press the Enter key.
d. From the Hardware Service Manager display, press F6 (print the
configuration).
e. To return to the AS/400 Main menu, press F3 (Exit) twice and then
press the Enter key.
f. Place the configuration list in the Basic System Operation, Administration,
and Problem Handling, SC41-5206-04 book.
__ 51. For information on how to make your disk unit operational, go to the
AS/400 Information Center. You can access the Information Center from the
AS/400 Information Center, SK3T-2027-03 or from the following web site:
http//www.as400.ibm.com/infocenter
__ 52. Keep all miscellaneous parts, such as wrap connectors, with the Service
Materials box or in a safe place.
The installation of the disk unit is complete.
Nonconcurrent procedure (system-unit powered off)
__ 1. If you have installed logical partitions on your system-unit, refer to the
AS/400 Information Center. At the AS/400 Information Center, you can
find instructions on powering down a system with logical partitions.
__ 2. Ensure that all jobs are complete.
__ 3. When all jobs are complete, type the following on an AS/400 command
line:
pwrdwnsys *immed
Press the Enter key.
Appendix C. Installing disk units in the 5065 or 5066 Expansion Unit 47