Models  870  and  890  -  Bulk  power  enclosure  (BPE) 
For  use  by  authorized  service  providers. 
Use  this  procedure  to  remove  or  replace  the  bulk  power  enclosure  (BPE)  on  the  Models  870  and  890. 
To  remove  the  bulk  power  enclosure  (BPE): 
1.  Locate  the  BPE  to  be  replaced  by  decoding  the  SRC.  See  the  System  reference  code  list,  or  Locations 
—  Models  870  and  890. 
2.  Perform  the  following: 
a.  Open  the  cover.  See  Models  870  and  890  -  Covers. 
b.  Note  the  state  of  the  ALL  FRUs  LEDs  in  the  BPE. 
c.  Press  the  (green)  Start  Service  button. 
d.  Only  proceed  if  the  ALL  the  BPR  (Bulk  Power  Regulator)  LEDs  are  off,  or  the  repair  has  been 
scheduled  (System  outage  -  EPO  off).
3.  Manually  turn  off  (to  the  right)  the  BPR’s  on-lock/off-unlock  switch  on  all  bulk  power  regulator’s  (BPRs) 
attached  to  the  bulk  power  assembly  (BPA)  side  being  repaired. 
4.  Verify  that  all  cables  are  labeled  for  plug  location,  and  then  unplug  all  cables  from  the  BPA  field 
replaceable  units  (FRUs).  Including,  the  bulk  power  controller  (BPC),  the  bulk  power  distribution  (BPD), 
and  the  BPR  cables  followed  by  the  ac  line  cord. 
5.  Remove  all  pluggable  FRUs  from  the  BPE,  including  the  BPR,  BPC,  BPD’s,  and  bulk  power  f-airmover 
(BPF). 
6.  Remove  the  four  mounting  screws.  Be  careful  to  retain  the  screws. 
Attention:  Do  not  remove  the  left  two  bottom  screws,  as  these  fasten  the  cage  rail  to  the  frame. 
7.  Slide  the  board/enclosure  FRU  (the  BPE)  out  of  the  frame. 
Note:  The  BPE  weighs  less  than  40  pounds. 
To  replace  the  bulk  power  enclosure  (BPE): 
1.  Slide  the  board/enclosure  FRU  (the  BPE)  into  the  frame  until  the  BPE  side  flanges  make  contact  with 
the  mounting  rails  using  the  right  side  guide  pins. 
2.  Fasten  with  the  four  mounting  screws. 
3.  Reinstall  the  pluggable  FRUs  into  the  BPE,  including  the  BPR,  BPC,  BPD’s,  and  BPF.  Be  sure  to 
check  the  board  connector  of  each  FRU  for  any  visible  signs  of  damage  (for  example,  broken  sockets) 
before  replugging  them  into  the  backplane.  Replace  any  FRU  found  to  be  damaged. 
Attention:  Ensure  that  all  the  BPR’s  on-lock/off-unlock  switches  are  in  the  ’off’  position  on  this  BPA 
before  proceeding. 
4.  Replug  all  cables  into  the  BPA  FRUs,  including  the  BPR,  BPC,  and  BPD’s  followed  by  the  ac  line  cord. 
Attention:  Ensure  that  the  UEPO  Bypass  switch  on  the  BPC  is  in  the  normal  ’left’  position. 
5.  Manually  set  all  BPR’s  on-lock/off-unlock  switches  to  the  ’on’  position  (to  the  left)  contained  in  the 
associated  BPA. 
6.  To   indicate  completion  of  these  steps,  press  the  (white)  Service  Complete  button  on  the  UEPO  panel.
This
  ends  the  procedure.
Models  870  and  890  -  Bulk  Power  F-airmover  (BPF) 
For  use  by  authorized  service  providers. 
Use  this  procedure  to  remove  or  replace  the  Bulk  Power  F-airmover  (BPF)  on  the  Models  870  and  890. 
The  BPF  is  located  immediately  to  the  right  of  the  Bulk  Power  Controller  (BPC),  and  mounted  vertically  in 
the  bulk  power  assembly  (BPA).  See  Locations  —  Models  870  and  890. 
To  remove  the  Bulk  Power  F-airmover  (BPF): 
 
Analyze  hardware  problems  95