v  Prevent  ESD-sensitive  cards  from  being  touched  accidentally  by  other  persons.  Reinstall  machine 
covers  when  you  are  not  working  on  the  machine.  Do  not  place  unprotected  ESD-sensitive  cards  on  a 
table. 
v  Be  careful  when  working  with  ESD-sensitive  cards  during  cold  weather  heating.  Cold  weather  heating 
causes  low  humidity  and  increases  the  risk  of  static  electricity.
System  safety  inspection 
For  use  by  authorized  service  providers. 
A  safety  inspection  for  the  system  should  be  performed: 
v  When  it  is  inspected  for  an  IBM  maintenance  agreement 
v  When  IBM  service  is  requested  and  no  service  has  recently  been  performed  by  IBM 
v  When  an  alterations  and  attachments  review  is  performed 
v  When  changes  have  been  made  to  the  equipment  that  might  affect  its  safety 
If  the  inspection  indicates  safety  conditions  that  are  not  acceptable,  the  conditions  must  be  corrected 
before  IBM  services  the  machine. 
Note:  The  correction  of  any  unsafe  condition  is  the  responsibility  of  the  owner  of  the  system. 
While  performing  this  inspection,  special  attention  must  be  given  to  these  areas: 
v  Feature  and  model  changes  and  engineering  change  (EC)  upgrades 
v  Additions  of  non-IBM  power  supplies  or  attachments 
v  Missing  safety  covers 
v  Removed,  faded,  or  painted-over  safety  labels 
v  Replacement  requirements  concerning  parts  for  primary  power 
v  Any  other  items  relating  to  the  product’s  safety 
Before  you  start,  you  must  have  completed  the  Electrical  Safety  Education  Course  for  IBM  Service 
Representatives  (self-study  course  77170  or  equivalent). 
You  will  need  these  items: 
v  An  IBM  service  representative  tool  kit  (or  equivalent) 
v  A  copy  of  iSeries  Service  Memorandums  (SMs),  which  include  engineering  change  announcements 
(ECAs)  and  service  aids  (SAs)  documents  for  the  system 
v  Latest  machine  history,  if  possible 
v  Electrical  Safety  for  IBM  Service  Representatives,  S229-8124 
v  A  Fluke**  8060A  digital  voltmeter  (part  8496278)  or  equivalent 
Perform  each  safety  check  on  the  following  pages: 
v  Covers  -  all  models 
v  AC  power  cords  -  all  models 
v  AC  safety  grounds 
v  Safety  labels 
v  Power  off  and  on  (system  unit)  -  all  models 
v  Internal  mechanical  inspection
Covers
  -  all  models:  For  use  by  authorized  service  providers. 
1.  Check  for  damaged  or  missing  covers. 
2.  Check  covers  for  sharp  edges.
 
586  Hardware  (Remove  and  Replace;  Part  Locations  and  Listings)