c.  Remove  the  mounting  screws  from  the  card  enclosure.  See  Final  assembly,  rear  -  Models  840  and 
SB3  processor  tower. 
d.  Slide  the  card  enclosure  partially  out  of  the  frame. 
e.  Disconnect  and  label  any  cables  from  the  card  that  you  wish  to  remove. 
f.  Turn  the  latch  counter  clockwise  and  lift  up  on  the  black  latch  to  release  the  card. 
Note:  If  you  are  removing  a  FC  2890,  then  you  must  use  dedicated  maintenance. 
g.  Remove  the  card  by  gently  pulling  it  out. 
h.  Install  the  card  in  to  the  system  by  reversing  the  card  removal  procedure  for  the  model  system  or 
tower  that  you  are  working  on. 
i.  Select  Power  on  domain  for  the  IOA  or  IOP  that  you  are  installing. 
Note:  To   the  right  of  the  description  field  you  will  see  one  or  both  of  the  following  symbols 
displayed. 
 
Symbol  Indication 
*  Indicates  the  location  to  which  the  system  will  assign  the  resource. 
>  Indicates  the  location  to  which  the  resource  was  last  assigned.
 
j.  Press  Enter.  The  Work  with  Controlling  Resources  display  will  appear. 
k.  Determine  the  location  where  you  want  to  assign  the  resource  and  select  Assign  to  for  that 
location. 
l.  After  exchanging  the  failing  item,  go  to  Verify  the  repair. 
Note:  If  you  have  exchanged  a  2766  or  2787  Fibre  Channel  IOA,  the  IBM  2105  disk  unit  subsystem 
must  be  updated  to  use  the  World-Wide  Port-Name  of  the  new  2766  or  2787  IOA.  This  name  can 
be  found  in  the  Port  worldwide  name  field  on  the  iSeries  by  displaying  detail  on  the  2766  or  2787 
IOA  Logical  Hardware  Resource  information  in  Hardware  Service  Manager  in  SST  or  DST. 
The  16-digit  World-Wide  Port-Name  can  also  be  determined  by  appending  the  digits  ″1000″  to  the 
beginning  of  the  12-digit  IEEE  Address  found  on  the  tailstock  label  of  the  Fibre  Channel  IOA.  Use 
the  ESS  Web  Interface  User’s  Guide  (SC26-7346)  to  update  the  World-Wide  Port-Name  in  the  host 
configuration  on  the  IBM  2105  ESS.  The  ESS  Web  Interface  User’s  Guide  can  also  be  found  at  the 
following  URL:  http://ssddom02.storage.ibm.com/disk/ess/documentation.html
This
  ends  the  procedure.
Models  840/SB3,  FC  8079-001  (lower  half),  FC  9079  cards  (dedicated) 
For  use  by  authorized  service  providers. 
Use  this  procedure  to  remove  or  replace  cards  (dedicated)  in  Models  840/SB3,  FC  8079-001  (lower  half), 
and  FC  9079. 
In  some  cases  you  do  not  need  to  power  down  the  system  to  change  PCI  cards.  Use  the  guidelines  in 
Models  840/SB3,  FC  8079-001  (lower  half),  FC  9079  cards  (concurrent)  to  determine  if  you  should  use 
dedicated  or  concurrent  remove  and  replace  procedures. 
CAUTION:
The  circuit  card  contains  lead  solder.  To  avoid  the  release  of  lead  (Pb)  into  the  environment,  do  not 
burn.  Discard  the  circuit  card  as  instructed  by  local  regulations.  (RSFTC234) 
Attention:  All  cards  are  sensitive  to  electrostatic  discharge  (see  Work  with  electrostatic  discharge-sensitive 
parts). 
To  remove  or  replace  cards  (dedicated): 
1.  Power  off  the  system.  See  Power  on/off  the  system  and  logical  partitions. 
2.  Disconnect  the  ac  power  cord  from  the  tower  that  you  are  working  on. 
 
78  Hardware  (Remove  and  Replace;  Part  Locations  and  Listings)