Step 1523-20
Note: Read the danger and caution notices under “Safety Notices” on page xi before continuing with this
procedure.
Perform the following:
1. Disconnect the mainline ac power cable from the customer’s ac power outlet.
2. Use a multimeter to measure the ac voltage at the customer’s ac power outlet.
Is
the ac voltage from 200 V ac to 240 V ac?
NO Inform the customer that the ac voltage at the power outlet is not correct.
This ends the procedure. Go to ″MAP 0410: Repair Checkout″ in the RS/6000 and Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
YES Replace the mainline ac power cable.
This ends the procedure. Go to ″MAP 0410: Repair Checkout″ in the RS/6000 and Eserver
pSeries Diagnostic Information for Multiple Bus Systems.
Chapter 3. Maintenance Analysis Procedures 105