Common Firmware Error Codes
Attention: Follow the procedure defined in “Checkpoint and Error Code Index” on page 161. If you
replace FRUs or perform an action and the problem is still not corrected, go to “MAP 1540: Minimum
Configuration” on page 110 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to ″MAP 0410: Repair Checkout″ in RS/6000 and
Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 9. Common Firmware Error Codes
Error Code Description Action/
Possible Failing FRU
B006 1403 Missing service processor resource 1. Update system firmware
Location: U0.1-P1/Y1
2. Primary drawer I/O backplane
Location: U0.1-P1
B006 1404 Service processor firmware fault 1. Update system firmware
Location: U0.1-P1/Y1
2. Primary drawer I/O backplane
Location: U0.1-P1
B006 1405 Service processor firmware fault 1. Update system firmware Location:
U0.1-P1/Y1
2. Primary drawer I/O backplane
Location: U0.1-P1
B006 1406 Service processor program error 1. Update system firmware
Location: U0.1-P1/Y1
2. Check for AIX updates
3. Primary drawer I/O backplane
Location: U0.1-P1
B006 1407 Service processor resource allocation
problem
1. Update system firmware
Location: U0.1-P1/Y1
2. Check for AIX updates
3. Primary drawer I/O backplane
Location: U0.1-P1
B006 1408 Service processor program error 1. Update system firmware
Location: U0.1-P1/Y1
2. Check for AIX updates
3. Primary drawer I/O backplane
Location: U0.1-P1
B006 1409 Service processor program error 1. Update system firmware
Location: U0.1-P1/Y1
2. Primary drawer I/O backplane
Location: U0.1-P1
B10F 1000 Service processor failure Primary I/O drawer backplane
Location: U0.1-P1
B10F 1002 Service processor failure Primary I/O drawer backplane
Location: U0.1-P1
B10F 1005 Service processor failure Primary I/O drawer backplane
Location: U0.1-P1
B10F 1007 Service processor failure Primary I/O drawer backplane
Location: U0.1-P1