EasyManuals Logo

IBM RS/6000 Enterprise Server M80 User Manual

IBM RS/6000 Enterprise Server M80
567 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #219 background imageLoading...
Page #219 background image
Table 6. Firmware Error Codes. (continued)
Error Code Description Action/
Possible Failing FRU
21A0 0xxx SCSI device errors Note: Before replacing any system
components:
1. Ensure that the controller and each
device on the SCSI bus is assigned a
unique SCSI ID.
2. Ensure SCSI bus is properly terminated:
3. Ensure SCSI signal and power cables are
securely connected and not damaged.
4. The location code information is required
to identify the ID of SCSI device failures
as well as to indicate the location of the
controller to which the device is attached.
Check the system error logs to determine
the location code information associated
with the error code.
21A0 0001 Test unit ready failed - hardware error Refer to the notes in error code 21A000xxx.
1. Replace the SCSI device.
2. Replace the SCSI cable.
3. Replace the SCSI controller.
21A0 0002 Test unit ready failed - sense data available Refer to the notes in error code 21A000xxx.
1. Replace the media (removable media
devices).
2. Replace the SCSI device.
21A0 0003 Send diagnostic failed Refer to the notes in error code 21A000xxx.
Replace the SCSI device.
21A0 0004 Send diagnostic failed - devofl cmd Refer to the notes in error code 21A000xxx.
Replace the SCSI device.
21E0 0xxx SCSI tape Refer to 21A00xxx for a description and
repair action for the xxx value.
21ED 0xxx SCSI changer Refer to 21A00xxx for a description and
repair action for the xxx value.
21EE 0xxx Other SCSI device type Refer to 21A00xxx for a description and
repair action for the xxx value.
21F0 0xxx SCSI CD-ROM Refer to 21A00xxx for a description and
repair action for the xxx value.
21F2 0xxx SCSI read/write optical Refer to 21A00xxx for a description and
repair action for the xxx value.
2200 0001 PCI Ethernet BNC/RJ-45 or PCI Ethernet
AUI/RJ-45 adapter
internal wrap test failure
Replace the Adapter
See note “Determining Location Code” on
page 160 for location code information
related to this error.
2200 1001 10/100 Mbps Ethernet PCI adapter
internal wrap test failure
Replace the Adapter
See “Determining Location Code” on page
160 for location code information related to
this error.
2201 0001 PCI auto LANstreamer token ring adapter
Adapter failed to complete hardware
initialization.
Replace the Adapter
See “Determining Location Code” on page
160 for location code information related to
this error.
Chapter 5. Error Code to FRU Index 201

Table of Contents

Other manuals for IBM RS/6000 Enterprise Server M80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM RS/6000 Enterprise Server M80 and is the answer not in the manual?

IBM RS/6000 Enterprise Server M80 Specifications

General IconGeneral
BrandIBM
ModelRS/6000 Enterprise Server M80
CategoryServer
LanguageEnglish

Related product manuals