Table 7. Service Processor Error Codes (continued)
Error Code Description Action/
Possible Failing FRU
4B2C 300A Processor system and IPL MOPS detected
32 MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2C 300B Processor system and IPL MOPS detected
128 MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2C 300C Processor system and IPL MOPS detected
256 MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2C 300D Processor system and IPL MOPS detected
512 MB (stacked) DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2C 300E Processor system and IPL MOPS detected
512 MB (unstacked) DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2C 301F Processor system and IPL MOPS detected
128 MB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2C 303A Processor system and IPL MOPS detected 1
GB DIMM fault
Memory DIMM
Locations: U1.1-P1-M1.n
U1.1-P1-M2.n
4B2C 515B Processor system and IPL MOPS detected
1100W ac power supply fault
1100W ac power supply
Locations: U1.1-V1
U1.1-V2
4B2C 51AC Processor system and IPL MOPS detected
595W ac power supply fault
595W ac power supply
Locations: U0.1-V1
U0.1-V2
4B2C 51AD Processor system and IPL MOPS detected
595W dc power supply fault
595W dc power supply
Locations: U0.1-V1
U0.1-V2
4B2C 51AE Processor system and IPL MOPS detected
1100W dc power supply fault
1100W dc power supply
Locations: U1.1-V1
U1.1-V2
4B2D 245B Processor system and IPL MOPS detected
2W 4M processor fault
Go to “MAP 1540: Minimum Configuration”
on page 110.
4B2D 245D Processor system and IPL MOPS detected
4W 4M processor fault
Go to “MAP 1540: Minimum Configuration”
on page 110.
4B2D 248B Processor system and IPL MOPS detected
primary I/O drawer operator panel fault
Operator Panel
Location: U0.1-L1
4B2D 24A5 Processor system and IPL MOPS detected
2W 500 MHz processor fault
Go to “MAP 1540: Minimum Configuration”
on page 110.
4B2D 24A6 Processor system and IPL MOPS detected
4W 500 MHz processor fault
Go to “MAP 1540: Minimum Configuration”
on page 110.
4B2D 25AB Processor system and IPL MOPS detected
400 MHz clock fault
400 MHz clock
Location: U1.1-P1.1.1
4B2D 25AD Processor system and IPL MOPS detected
540 MHz clock fault
540 MHz clock
Location: U1.1-P1.1.1
330 Service Guide