EasyManuals Logo

IBM System x3500 Service Guide

IBM System x3500
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background image
hot-swap component for any additional procedures that you might have to
perform before you remove or install the component.
v When you are finished working on the server, reinstall all safety shields, guards,
labels, and ground wires.
v You can install a maximum of two IDE devices in the server.
v For a list of supported optional devices for the server, see http://www.ibm.com/us/
compact/.
System reliability guidelines
To help ensure proper cooling and system reliability, make sure that the following
requirements are next:
v Each of the drive bays has a drive or a filler panel and electromagnetic
compatibility (EMC) shield installed in it.
v If the server has redundant power, each of the power-supply bays has a power
supply installed in it.
v There is adequate space around the server to allow the server cooling system to
work properly. Leave approximately 50 mm (2.0 in.) of open space around the
front and rear of the server. Do not place objects in front of the fans. For proper
cooling and airflow, replace the server cover before you turn on the server.
Operating the server for extended periods of time (more than 30 minutes) with
the server cover removed might damage server components.
v You have followed the cabling instructions that come with optional adapters.
v You have replaced a failed fan as soon as possible.
v You have replaced a hot-swap drive within 2 minutes of removal.
v You do not remove the air baffles or air ducts while the server is running.
Operating the server without the air baffle or air ducts might cause the
microprocessor to overheat.
v Microprocessor socket 2 always contains either a microprocessor baffle or a
microprocessor and heat sink.
Working inside the server with the power on
Attention: Static electricity that is released to internal server components when
the server is powered-on might cause the server to halt, which might result in the
loss of data. To avoid this potential problem, always use an electrostatic-discharge
wrist strap or other grounding system when you work inside the server with the
power on.
The server supports hot-plug, hot-add, and hot-swap devices and is designed to
operate safely while it is turned on and the cover is removed. Follow these
guidelines when you work inside a server that is turned on:
v Avoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirts
before you work inside the server; do not wear cuff links while you are you work
inside the server.
v Do not allow your necktie or scarf to hang inside the server.
v Remove jewelry, such as bracelets, necklaces, rings, and loose-fitting wrist
watches.
v Remove items from your shirt pocket, such as pens and pencils, that might fall
into the server as you lean over it.
v Avoid dropping any metallic objects, such as paper clips, hairpins, and screws,
into the server.
56 IBM System x3500 Type 7977: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM System x3500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3500 and is the answer not in the manual?

IBM System x3500 Specifications

General IconGeneral
ChipsetIntel 5000P
Maximum Memory48 GB
Memory Slots12
Network InterfaceDual Gigabit Ethernet
ProcessorIntel Xeon 5400/5300/5200 series
Form Factor5U Tower
Memory TypeDDR2 FB-DIMM
StorageUp to 6 x 3.5" SAS/SATA HDDs
RAID SupportRAID 0, 1
Expansion Slots6 x PCI-E slots
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESX Server

Related product manuals