Table 36. Warning events (continued)
Event Code Message Text and Description Details and Solution
4151 Download of drive rmware image
completed, but rmware revision didn’t
change after restart.
Check if the uploaded rmware image is
matching your drive type and generation.
Ensure that the image le isn’t corrupted.
Download a new image from the drive
vendor's website if you aren’t sure about le
integrity.
4152 KMIP Connection refused The selected port on the target machine isn’t
open. The connection is refused. Check that the
server application is running on the target
machine and the rewall isn’t blocking the
selected port. Contact IT Personnel to verify
the port settings.
4153 KMIP Server doesn’t trust the client
certicate.
Use a client certicate that is signed by a
trusted certicate authority (CA) or manually
select the untrusted certicate on the server
side and trust it (not available on all servers).
4154 KMIP Ping to server failed The target machine couldn't be reached, so no
network connection possible.
Verify that the IP address in the settings is
correct.
Check that the target machine is powered
and connected to the network.
Check the network cable.
Verify that the Firewall setting on the target
machine allows ping requests and responses.
4155 KMIP No route to host The target machine couldn't be reached. The
network route to the machine isn’t available.
Check your IP settings (IP address, Gateway
and Netmask) and verify it with your IT
personnel.
Check that the Firewall settings on the target
machine are correct.
4156 KMIP Handshake failure The TLS connection couldn't be established
because of Handshake errors during certicate
exchange.
Check the certicates on server and client
side for valid entries and that they are still
valid and not expired.
Verify that TLS1.2 is enabled on the server.
Check the client and server date/time for
current time.
Ask your IT personnel for new and valid
certicates.