Power  problems 
 
v  Follow  the  suggested  actions  in  the  order  in  which  they  are  listed  in  the  Action  column  until  the  problem 
is  solved. 
v  See  the  Problem  Determination  and  Service  Guide  on  the  IBM  System  x  Documentation  CD  to  determine  which 
components  are  customer  replaceable  units  (CRU)  and  which  components  are  field  replaceable  units 
(FRU). 
v  If  an  action  step  is  preceded  by  “(Trained  service  technician  only),”  that  step  must  be  performed  only  by  a 
trained  service  technician. 
Symptom  Action 
The  power-control  button  does 
not  work  (the  server  does  not 
start). 
Note:  The  power-control  button 
will  not  function  until  20 
seconds  after  the  server  has 
been  connected  to  ac  power. 
1.  Make  sure  that  the  power-control  button  is  working  correctly: 
a.  Disconnect  the  server  power  cords. 
b.  Reconnect  the  power  cords. 
c.  (Trained  service  technician  only)  Reseat  the  operator  information  panel 
cables,  and  then  repeat  steps  1a  and  1b. 
v  (Trained  service  technician  only)  If  the  server  starts,  reseat  the  operator 
information  panel.  If  the  problem  remains,  replace  the  operator 
information  panel.
2.
  Make  sure  that: 
v  The  power  cords  are  correctly  connected  to  the  server  and  to  a  working 
electrical  outlet. 
v  The  type  of  memory  that  is  installed  is  correct. 
v  The  DIMM  is  fully  seated. 
v  The  LEDs  on  the  power  supply  do  not  indicate  a  problem. 
v  The  microprocessors  are  installed  in  the  correct  sequence.
3.
  Reseat  the  following  components: 
a.  DIMMs 
b.  (Trained  service  technician  only)  Power  switch  connector 
c.  (Trained  service  technician  only)  Power  backplane
4.
  Replace  the  following  components  one  at  a  time,  in  the  order  shown,  restarting 
the  server  each  time: 
a.  DIMMs 
b.  (Trained  service  technician  only)  Power  switch  connector 
c.  (Trained  service  technician  only)  Power  backplane 
d.  (Trained  service  technician  only)  System  board
5.
  If  you  just  installed  an  optional  device,  remove  it,  and  restart  the  server.  If  the 
server  now  starts,  you  might  have  installed  more  devices  than  the  power  supply 
supports. 
6.  See  the  Problem  Determination  and  Service  Guide  on  the  IBM  System  x 
Documentation  CD. 
The  server  does  not  turn  off. 
1.  Determine  whether  you  are  using  an  Advanced  Configuration  and  Power 
Interface  (ACPI)  or  a  non-ACPI  operating  system.  If  you  are  using  a  non-ACPI 
operating  system,  complete  the  following  steps: 
a.  Press  Ctrl+Alt+Delete. 
b.  Turn  off  the  server  by  pressing  the  power-control  button  for  5  seconds. 
c.  Restart  the  server. 
d.  If  the  server  fails  POST  and  the  power-control  button  does  not  work, 
disconnect  the  power  cord  for  20  seconds;  then,  reconnect  the  power  cord 
and  restart  the  server.
2.
  If  the  problem  remains  or  if  you  are  using  an  ACPI-aware  operating  system, 
suspect  the  System  board. 
 
86  IBM  System  x3500  Type  7977:  Installation  Guide