grouping  the  first  two  physical  drives  in  the  ServeRAID  Manager  tree  into  an  array 
and  creating  a  RAID  level-1  logical  drive.  If  you  select  custom  configuration,  you 
can  select  the  two  physical  drives  that  you  want  to  group  into  an  array  and  create  a 
hot-spare  drive. 
Using  express  configuration:  To  use  express  configuration,  complete  the 
following  steps: 
1.  In  the  ServeRAID  Manager  tree,  click  the  controller. 
2.  Click  Express  configuration. 
3.  Click  Next.  The  “Configuration  summary”  window  opens. 
4.  In  the  “Configuration  summary”  window,  review  the  information.  To  change  the 
configuration,  click  Modify  arrays. 
5.  Click  Apply;  when  you  are  asked  whether  you  want  to  apply  the  new 
configuration,  click  Yes.  The  configuration  is  saved  in  the  controller  and  in  the 
physical  drives. 
6.  Exit  from  ServeRAID  Manager  and  remove  the  CD  from  the  CD  drive. 
7.  Restart  the  server.
Using
  custom  configuration:  To  use  custom  configuration,  complete  the 
following  steps: 
 
1.  In  the  ServeRAID  Manager  tree,  click  the  controller. 
 
2.  Click  Custom  configuration. 
 
3.  Click  Next.  The  “Create  arrays”  window  opens. 
 
4.  From  the  list  of  ready  drives,  select  the  two  drives  that  you  want  to  group  into 
the  array. 
 
5.  Click  the  (Add  selected  drives)  icon  to  add  the  drives  to  the  array. 
 
6.  If  you  want  to  configure  a  hot-spare  drive,  complete  the  following  steps: 
a.  Click  the  Spares  tab. 
b.  Select  the  physical  drive  that  you  want  to  designate  as  the  hot-spare  drive, 
and  click  the  (Add  selected  drives)  icon.
  7.  Click  Next.  The  “Configuration  summary”  window  opens. 
 
8.  Review  the  information  in  the  “Configuration  summary”  window.  To  change  the 
configuration,  click  Back. 
 
9.  Click  Apply;  then,  click  Yes  when  asked  if  you  want  to  apply  the  new 
configuration.  The  configuration  is  saved  in  the  controller  and  in  the  physical 
drives. 
10.  Exit  from  ServeRAID  Manager  and  remove  the  CD  from  the  CD-RW/DVD 
drive. 
11.  Restart  the  server.
Viewing  the  configuration 
You  can  use  ServeRAID  Manager  to  view  information  about  RAID  controllers  and 
the  RAID  subsystem  (such  as  arrays,  logical  drives,  hot-spare  drives,  and  physical 
drives).  When  you  click  an  object  in  the  ServeRAID  Manager  tree,  information  about 
that  object  is  displayed  in  the  right  pane.  To   display  a  list  of  available  actions  for  an 
object,  click  the  object  and  click  Actions. 
 
60  IBM  System  x3500  Type  7977:  Installation  Guide