v  Follow  the  suggested  actions  in  the  order  in  which  they  are  listed  in  the  Action  column  until  the  problem 
is  solved. 
v  See  the  Problem  Determination  and  Service  Guide  on  the  IBM  System  x  Documentation  CD  to  determine  which 
components  are  customer  replaceable  units  (CRU)  and  which  components  are  field  replaceable  units 
(FRU). 
v  If  an  action  step  is  preceded  by  “(Trained  service  technician  only),”  that  step  must  be  performed  only  by  a 
trained  service  technician. 
Symptom  Action 
The  server  unexpectedly  shuts 
down,  and  the  LEDs  on  the 
operator  information  panel  are 
not  lit. 
See  the  Problem  Determination  and  Service  Guide  on  the  IBM  System  x 
Documentation  CD.
 
Serial  port  problems 
 
v  Follow  the  suggested  actions  in  the  order  in  which  they  are  listed  in  the  Action  column  until  the  problem 
is  solved. 
v  See  the  Problem  Determination  and  Service  Guide  on  the  IBM  System  x  Documentation  CD  to  determine  which 
components  are  customer  replaceable  units  (CRU)  and  which  components  are  field  replaceable  units 
(FRU). 
v  If  an  action  step  is  preceded  by  “(Trained  service  technician  only),”  that  step  must  be  performed  only  by  a 
trained  service  technician. 
Symptom  Action 
The  number  of  serial  ports  that 
are  identified  by  the  operating 
system  is  less  than  the  number 
of  installed  serial  ports. 
1.  Make  sure  that: 
v  Each  port  is  assigned  a  unique  address  in  the  Configuration/Setup  Utility 
program  and  none  of  the  serial  ports  is  disabled. 
v  The  serial  port  adapter  (if  one  is  present)  is  seated  correctly.
2.
  Reseat  the  serial  port  adapter. 
3.  Replace  the  serial  port  adapter. 
A  serial  device  does  not  work. 
1.  Make  sure  that: 
v  The  device  is  compatible  with  the  server. 
v  The  serial  port  is  enabled  and  is  assigned  a  unique  address. 
v  The  device  is  connected  to  the  correct  connector  (see  “Rear  view”  on  page 
37).
2.
  Reseat  the  following  components: 
a.  Failing  serial  device 
b.  Serial  cable 
c.  Remote  Supervisor  Adapter  II  SlimLine  (if  one  is  present)
3.
  Replace  the  following  components  one  at  a  time,  in  the  order  shown,  restarting 
the  server  each  time: 
a.  Failing  serial  device 
b.  Serial  cable 
c.  Remote  Supervisor  Adapter  II  SlimLine  (if  one  is  present) 
d.  (Trained  service  technician  only)  System  board
 
 
Chapter  5.  Solving  problems  87