Attention:  Do  not  touch  the  thermal  grease  on  the  bottom  of  the  heat  sink 
after  you  remove  the  plastic  cover.  Touching  the  thermal  grease  will  contaminate 
it. 
9.  Reinstall  the  microprocessor  air  duct  on  the  fan  cage.
If
  you  have  other  devices  to  install  or  remove,  do  so  now.  Otherwise,  go  to 
“Completing  the  installation”  on  page  30. 
Installing  an  adapter 
The  following  notes  describe  the  types  of  adapters  that  the  server  supports  and 
other  information  that  you  must  consider  when  you  install  an  adapter: 
v  Locate  the  documentation  that  comes  with  the  adapter  and  follow  those 
instructions  in  addition  to  the  instructions  in  this  section.  If  you  must  change  the 
switch  or  jumper  settings  on  the  adapter,  follow  the  instructions  that  come  with 
the  adapter. 
v  Avoid  touching  the  components  and  gold-edge  connectors  on  the  adapter. 
v  PCI  slot  6  supports  half-length  5.0  V  PCI  adapters  only. 
v  PCI  slot  1  supports  half-length  3.3  V  PCI  adapters  only. 
v  PCI  slots  2  through  5  support  full-length  3.3  V  signaling  adapters  only. 
v  The  PCI  configuration: 
–  Slot  1  is  a  PCI-Express  x8  slot  with  x4  links,  PCI  Express  1.0a  compliant. 
–  Slot  2  and  3  are  PCI-Express  x8  slots  with  x8  links,  PCI  Express  1.0a 
compliant.  is  the  default  slot  for  the  optional  ServeRAID-10is  controller  or  the 
ServeRAID-8s  controller. 
–  Slots  4  and  5  are  PCI-X  133/64  slots,  PCI-X  2.0  compliant. 
–  Slot  6  is  a  PCI  33/32  slot,  PCI  2.2  compliant.
Note:
  The  ServeRAID-8k,  ServeRAID-8s,  and  the  optional  ServeRAID-10is  SAS 
controllers  override  the  standard  functionality  of  the  integrated  SAS/SATA 
controller  with  RAID  capabilities. 
v  The  system  scans  PCI  slots  1  through  6  to  assign  system  resources.  The  system 
then  starts  (boots)  the  system  devices  in  the  following  order,  if  you  have  not 
changed  the  default  boot  precedence:  integrated  Ethernet  controller, 
ServeRAID-8k  SAS  controller,  and  then  PCI,  PCI-X,  and  PCI-Express  slots. 
Note:  To   change  the  boot  precedence  for  PCI  and  PCI-X  devices,  start  the 
Configuration/Setup  Utility  program  and  select  Start  Options  from  the  main 
menu.  See  the  User’s  Guide  on  the  IBM  System  x  Documentation  CD  for  details 
about  using  the  Configuration/Setup  Utility  program. 
v  The  server  uses  a  rotational  interrupt  technique  to  configure  PCI  adapters  so  that 
you  can  install  PCI  adapters  that  do  not  support  sharing  of  PCI  interrupts. 
v  In  models  with  12  hard  disk  drives,  a  ServeRAID-8s  controller  must  be  installed 
in  PCI  slot  2  and  a  ServeRAID-8k  controller  in  the  ServeRAID  connector  on  the 
system  board.
To
  install  an  adapter,  complete  the  following  steps: 
1.  Read  the  safety  information  that  begins  on  page  vii  and  “Installation  guidelines” 
on  page  7. 
2.  Turn  off  the  server  and  peripheral  devices,  and  disconnect  the  power  cords  and 
all  external  cables.  Remove  the  left-side  cover. 
 
Chapter  2.  Installing  optional  devices  27