8
SET MODE
8-5
» SET > Function
AFC Limit (Default: ON)
Select whether to limit the operating range of the AFC
(Automatic Frequency Control) function, or not.
• OFF: Turns OFF the function.
• ON:
Limits the operating range of the AFC function.
The limit value differs depending on the IF
lter width as described below.
IF Filter width AFC limit value
15 kHz ±10 kHz
10 kHz ±7 kHz
7 kHz ±5 kHz
[NOTCH] Switch (SSB) (Default: Auto/Manual)
[NOTCH] Switch (AM) (Default: Auto/Manual)
Selects the notch function used in the SSB or AM mode.
• Auto: Only the Auto Notch function can be
used.
• Manual: Only the Manual Notch function can
be used.
• Auto/Manual: Both the Auto and Manual Notch
functions can be used.
SSB/CW Synchronous Tuning (Default: OFF)
Turns the Displayed Frequency Shift function ON or OFF.
This function automatically shifts the frequency to
match the CW pitch when the operating mode is
toggled between SSB and CW.
• OFF: Turns OFF the function.
• ON: When the operating mode is changed
between SSB and CW, the operating
frequency shifts by the offset amount.
CW Normal Side (Default: USB)
Selects the carrier point in the CW normal mode.
• LSB: Sets the carrier point to the LSB side.
• USB: Sets the carrier point to the USB side.
Keyboard Type (Default: Full Keyboard)
Sets the keyboard entry type to Ten-Key or Full
Keyboard.
Full Keyboard Layout (Default: English)
Selects the on-screen keyboard layout between
English, German and French.
My Station
» SET > My Station
My Call Sign (DV)
The transceiver has a total of 6 memories to save
your own call signs for DV mode.
You can enter a call sign of up to 8 digits. Also, a note
of up to 4 characters, for operating transceiver type,
area, and so on, can be entered.
TX Message (DV)
The transceiver has a total of 5 memories to save
short messages for simultaneous transmission in the
DV mode.
Enter a message of up to 20 alphanumeric characters
for each memory.
LTo transmit no message, select “OFF.”
My Call Sign (DD)
The transceiver has a total of 6 memories to save
your own call signs for DD mode.
You can enter a call sign of up to 8 digits. Also, a note
of up to 4 characters, for operating transceiver type,
area, and so on, can be entered.
Screen Capture [POWER] Switch (Default: OFF)
Assigns the Screen Capture function to
.
• OFF:
does not act as the Screen Capture
key.
• ON:
acts as the Screen Capture key.
Screen Capture File Type (Default: PNG)
Sets the le format for the Screen Capture function to
PNG or BMP.
» SET > Function > REF Adjust
REF Adjust
Adjusts the internal reference frequency.
REF Adjust (FINE)
Fine tune the value set in “REF Adjust.”
NOTE: The default setting of “REF Adjust” may differ
slightly, depending on the transceiver’s version.
Function (Continued)