61
9
CONNECTIONS AND MAINTENANCE
9
MB-75 installation
An optional MB-75 FLUSH MOUNT KIT is available for
mounting the transceiver to a flat surface such as an instru-
ment panel.
KEEP the transceiver and microphone at least 1 meter
away from your vessel’s magnetic navigation compass.
q Using the template on the last page, carefully cut a hole
into the instrument panel (or wherever you plan to mount
the transceiver).
w Slide the transceiver through the hole as shown below.
e Attach the 2 supplied bolts (M5 × 8 mm) on either side of
the IC-M505.
r Attach the clamps on either side of the IC-M505.
•MakesurethattheclampsalignparalleltotheIC-M505’sbody.
r
r
Clamp
Supplied bolt
t Tighten the end bolts on the clamps (rotate clockwise) so
that the clamps press firmly against the inside of the in-
strument control panel.
y Tighten the locking nuts (rotate counterclockwise) so that
the IC-M505 is securely mounted in position as below.
t
y
End bolt
Locking nut
u Connect the antenna and power cable, then return the
instrument control panel to its original place.