CONNECTIONS AND MAINTENANCE
9
r Return the cables and screws to the original position.
•Besurenotupsidedowntheatcable.
CAUTION:
•When re-assemblingthe case and tighteningthe
screws, you must keep the specified torque (0.0.07
N.m). Otherwise the transceiver may be damaged
(torque too high) or lose waterproof efficiency (torque
too low).
•Whenuninstallingtheoptionalunit,removeitvertically.
Wiggling the unit from side to side may damage the op-
tional unit's connector.
HM-162E installation
The optional HM-162E should be installed to the transceiver
using the supplied connection cable.
The connector of the connection cable can be installed into
a cabinet, wall, etc., as a built-in plug.
For longer distance remote operation, the optional extension
cable, OPC-1541 (6 m; connecting between transceiver and
the connection cable), is available, and up to two OPC-1541
can be added.