FC6A S
ERIES
M
ICRO
S
MART
A
LL
-
IN
-O
NE
T
YPE
C
OMMUNICATION
M
ANUAL
FC9Y-B1730 11-7
11: W
EB
S
ERVER
System Web Page Overview
The system web page of the FC6A Series MicroSmart consists of the following files.
/system/index.html: The system web top page that displays the FC6A Series MicroSmart status.
/system/batch_monitor.html: Batch monitor to monitor a group of data registers.
/system/custom_monitor.html: Custom monitor to register and monitor a maximum of 30 data registers or internal relays.
/system/lcd_monitor.html: The system web page with the HMI module LCD monitor function.
/system/device_read.cgi: CGI for reading device data used by JavaScript.
/system/device_write.cgi: CGI for writing device data used by JavaScript.
Separately from these system web pages, the FC6A Series MicroSmart project can contain user web pages with user-defined page
data.
The placement of files that are set on the WindLDR Project window is reflected under /user/.
Web Data Type
The following web data types can be specified in batch monitor, custom monitor.
Note: BIN-B is used in the custom monitor when internal relay is monitored. 0000 is OFF and 0001 is ON.
Data Type Data Size Valid Range
HEX-W Hexadecimal 1 word 0000 to FFFF
HEX-D Hexadecimal 2 words 00000000 to FFFFFFFF
DEC-W Decimal 1 word 0 to 65535
DEC-I Decimal 1 word -32768 to 32767
DEC-D Decimal 2 words 0 to 4294967296
DEC-L Decimal 2 words -2147483648 to 2147483647
DEC-F Decimal 2 words IEEE754 format. Digits is 7.
BIN-B Binary 1 bit 0000 or 0001 (Note)