Work Settings Audible Alarms
155
Height Alarm, Laser Catch, Sensor Loss
You can enable/disable the Alarm Function by pressing
the corresponding buttons for Elevation Alarm, Laser
Catch and Sensor Loss. A button highlighted means that
it is enabled:
Elevation Alarm when the Height Alarm is activated
from the Main Screen the horn will notify the
operator that an alarm situation exists.
Laser Catch when activated the horn will sound
when the laser beam has been caught by the system.
Sensor Loss a horn will notify the operator that
there is a lost sensor signal.