Calibration
184
Bad Bucket Calibration using the Manual Procedure (cont.)
Bucket Sensor on dog bone:
Its not possible to use the manual procedure when the bucket Sensor is attached to the dog bone. Use the automatic procedure
instead.
Bad Tilt Calibration
Left/Right tilt information is swapped:
Tilt A & B got mixed up:
The Sensors got assigned (paired) backwards
The Sensors got put on the support plates backwards.
The support plates got installed on the triangle holder backwards.
The support plates got installed on the triangle mount with the wrong orientation.
Bad accuracy:
Re-check the bucket accuracy with the tilt functionality DISABLED:
If bad, re-calibrate the bucket.
If good, proceed to next.
Re-check the AB measurement between the bucket pivot point and tilt rotational axis:
Best to measure with the tilt axis perfectly horizontal as you may use a long spirit level to move the axis.
Make sure to measure straight vertical, NOT diagonal.
Be sure to check your unit length.
Check to make sure the blade is horizontal AFTER the bucket was curled in the 35° 55° range.