Using the triangle mount:
Tilt A & B got reversed:
The Sensors to assigned (paired) backwards.
The Sensors got put on the support plates backwards.
The support plates got installed on the triangle mount backwards.
The support plates got installed on the triangle mount with the wrong orientation.
NOT using the triangle mount:
Sensors Tilt A & Tilt B are not oriented properly to each other.
Calibration
185
Bad Tilt Calibration (cont.)
Problems During the Automatic Laser Receiver Calibration
If the Combo Sensor got installed on the bottom 1/3 of the dipper stick you may use the automatic calibration procedure for the laser
receiver. Otherwise you need to use the Manual method.
Make sure that there is no slope set in the rotating laser.
Make sure that you selected the finest deadband on the hand detector for shot #1.
I can’t reach the bucket pivot point with the hand held detector for shot #1:
Setup the tripod lower even if you may need to raise the main boom for shot #3.
When the dipper stick is fully pulled in the reception field is almost horizontal so it won’t catch the laser beam or get me an on-grade signal
for shot #2:
Open the dipper stick until it catches the laser beam. Its recommended, but not mandatory, to fully pull in the dipper stick.