IDS 816 700-283-02I Issued September 2009
Sub-location 4 Partition Arm Options
1
ON Enable instant arm
OFF Disable instant arm
2
ON Enable instant key-switch arm
OFF Disable instant key-switch arm
3
ON Enable quick arm key
OFF Disable quick arm key
4
Enable quick stay arm key
Disable quick stay arm key
5
ON Enable auto stay arm if no exit zone is triggered
OFF Panel away arms regardless if zone is triggered
6
ON
Enable auto stay arm if no exit zone is triggered when
arming with a key-switch (or remote)
OFF
Disable auto stay arm if no exit zone is triggered when
arming with a key-switch (or remote)
7
ON Enable forced arm
OFF Disable forced arm
8
Enable arm with zones in the entry route violated
OFF Disable arm with zones in the entry route violated
10
ON Enable siren toot on arm
OFF Disable siren toot on arm
11
ON Enable siren toot on disarm
OFF Disable siren soot on disarm
12
ON Enable the entry beep
OFF Disable the entry beep
13
ON Enable the exit beep
OFF Disable the exit beep
14
15
ON Enable auto disarm
OFF Disable auto disarm
Default values are shaded
Quick Arm:
This option allows the user to arm the panel by holding down the [1] key for two seconds until the
keypad beeps.
Force Arm:
With this option enabled, the panel will arm with violated zones e.g. an open window. When the panel
arms, any violated zone is bypassed. If bypassed zones restore during the arm cycle (e.g. a window is
closed), the zone is automatically re-activated (un-bypassed).
Siren Toot on Away Arm / Disarm:
This option allows the user an audible confirmation that arming or disarming of the panel has occurred.
The siren can be programmed to give a short beep after successful arming, and two short beeps after
disarming. This is useful when used in conjunction remote or key-switch arming/disarming.