IDS 816 700-283-02I Issued September 2009
44
Engineer Reset:
If enabled this option prevents arming the panel after an alarm condition has occurred. The panel can
only be armed after the engineer has entered a valid installer code. A trouble condition will be displayed
on the keypad if enabled in location 40.
Sub-location 5 Partition Options
LED
ON / OFF
Action
1
ON
Enable automatic re-enabling of shutdown zones
at the time of the dialler test.
OFF
Disable automatic re-enabling of shutdown
zones at the time of the dialler test.
2
ON
Enable bypassing of common zones
OFF
Disable bypassing of common zones
3
ON Enable delay before communications
OFF Disable delay before communications
4
ON Enable keypad lockout
OFF Disable keypad lockout
5
ON Enable user phone access
OFF Disable user phone access
6
ON Enable silent keypad panic
OFF Disable silent keypad panic
Default values are shaded
Sub-location 6 Exit Delay Period
Value
Time-out Delay
Value
Time-out Delay
0 3 Seconds 8 2 Minutes
1 10 Seconds 9 3 Minutes
2
15 Seconds
10
4 Minutes
3
20 Seconds
11
5 Minutes
4 25 Seconds 12 10 Minutes
5 30 Seconds (default) 13 15 Minutes
6 45 Seconds 14 18 Minutes
7 1 Minute 15 21 Minutes
The exit delay will begin after the entry of a valid user code (or pressing of the [1] or [6], initiating the
quick-arm function). During this period, it is permissible to violate Entry/Exit and Follower zones without
causing an alarm condition thus allowing exit from the premises.
Select the appropriate exit delay period from the table above. If an instant zone is violated
during this period, an alarm condition will immediately be registered. Select the appropriate value for the
primary exit delay from the table.
Sub-location 7 Primary Entry Delay Time
(Values identical to Sub-location 6) This entry delay begins after the violation of a primary Entry/Exit zone.
During this, it is permissible to violate follower zones without causing an alarm condition if an Entry/Exit
zone was violated first.
If a follower zone is violated without a prior Entry/Exit zone violation, it will be treated as an
instant zone. If an instant zone is violated during this period, an alarm condition will immediately be
registered. Select the appropriate value for the primary entry delay from the same table for sub-location 6.