31
UK
*** This message is only displayed for 3-wire operation. For 2-wire operation undervoltage
is detected and displayed. If OU2 is not used for the application, the message can be
suppressed by defining a switching function for OU2 (→ 9.3.1).
10.4 Setting ranges
SP1 / SP2 rP1 / rP2 ASP AEP
ΔP
min max min max min max min max
PI2893
bar -0.96 25.00 -1.00 24.96 -1.00 18.74 5.24 25.00 0.02
PSI -13.8 362.7 -14.4 362.1 -14.4 271.8 76.2 362.7 0.3
MPa -0.096 2.500 -0.100 2.496 -0.100 1.874 0.524 2.500 0.002
PI2814
bar -0.98 16.0 -1.0 15.98 -1.0 12.0 3.0 16.0 0.02
psi -14.2 232.0 -14.6 231.6 -14.6 174 43.6 232.0 0.2
MPa -0.098 1.6 -0.1 1.598 -0.1 1.2 0.3 1.6 0.002
PI2894
bar -0.98 10.00 -1.00 9.98 -1.00 7.50 1.50 10.00 0.01
PSI -14.2 145.0 -14.5 144.7 -14.5 108.7 21.8 145.0 0.1
MPa -0.098 1.000 -0.100 0.998 -0.100 0.750 0.150 1.000 0.001
PI2815
bar -0.99 6.0 -1.0 5.99 -1.0 4.5 0.5 6.0 0.005
psi -14.4 87.0 -14.5 86.9 -14.5 65.3 7.3 87.0 0.1
kPa -99.0 600.0 -100.0 599.0 -100.0 450.0 50.0 600.0 0.5
PI2895
bar -0.990 4.000 -1.000 3.990 -1.000 3.000 0.000 4.000 0.005
PSI -14.35 58.00 -14.50 57.85 -14.50 43.50 0.00 58.00 0.05
kPa -99.0 400.0 -100.0 399.0 -100.0 300.0 0.0 400.0 0.5
PI2896
bar -0.120 2.500 -0.124 2.496 -0.124 1.880 0.500 2.500 0.002
PSI -1.74 36.27 -1.80 36.21 -1.80 27.27 7.26 36.27 0.03
kPa -12.0 250.0 -12.4 249.6 -12.4 188.0 50.0 250.0 0.2
in H
2
O
-48 1004 -50 1002 -50 755 201 1004 1
mWS
-1.22 25.49 -1.26 25.45 -1.26 19.17 5.10 25.49 0.01
PI2899
mbar -998 1000 -1000 998 -1000 500 -500 1000 1
PSI -14.45 14.50 -14.50 14.45 -14.50 7.25 -7.25 14.50 0.05
kPa -99.8 100.0 -100.0 99.8 -100.0 50.0 -50.0 100.0 0.1
in H
2
O
-400 401 -401 400 -401 201 -201 401 1
mWS
-10.18 10.20 -10.20 10.18 -10.20 5.10 -5.10 10.20 0.01
ΔP = step increment