eg.: Set 20 minutes for the scanner to be automatically turn off.
1. Read the "Enter Setup" barcode;
2. Read the "Enter Auto Power Off" barcode;
3. Read the "20min" barcode;
4. Read the "Exit with Save" barcode.
Note: If you want to keep the scanner power on all the time, read "Exit
Auto Power Off" in stead of step 3 and 4.
1.2 Transmit Buffer
During the 2.4Ghz connection, the BCST-20 Scanner uses a 256KB
memory as a data buffer, and sends the collected data to the host
computer one by one via the 2.4Ghz. Upon reading a barcode
successfully, the scanner responds with one short beep and its LED
indicator becomes green and goes off quickly. However, the host
computer may not receive the data immediately if getting out of range.
With the 256KB transmit buffer, the scanner can ignore the transmis-
sion status and keep on reading barcodes until the buffer is full. When
the buffer is full, the scanner will respond with a long beep (low tone),
this reminds the user that the space of buffer is not enough and can
not read barcode any more. Once the Buffer is