IDS440 Users Manual version 4.2
60
IDS440 Specifications
Display 1 inch x 6-digit numeric, 6 LED status indicators.
Keyboard Sealed keyboard with tactile feel.
I/O Ports Load Cell Interface Port.
Serial port 1 - RS232 or Cur. Loop.
Serial port 2 - RS232 or RS485.
9 TTL outputs.
8 TTL inputs.
Display Graduations 120,000 graduations (industrial)
10,000 hb44.
Display Increments 1, x2, x5, x10, x20, x50, x100.
Decimal Point 0 to 4 decimal places.
Internal Graduations 1,024,000.
Conversion Rate 60/sec @60hz line frequency (HS version 100/sec @ 60hz)
Signal Sensitivity 0.1 uV/graduation (min).
Signal Range 0.5 mV/V - 3.9 mV/V.
Load Cell Excitation 10 VDC.
Load Cell Current 240ma (8, 350 ohm Load Cells).
Auto Zero Tracking 0 to 60 grads, @1/4 grad increments.
Auto Zero Delay 0 to 25 sec, @0.1 sec increments.
Motion Detect 0 to 60 grads, @1/4 grad increments.
Motion Delay 0 to 25 sec, @0.1 sec increments.
Digital Filter 19 settings (0 to 18).
Digital Calibration Front Panel - zero & span stored in EAROM.
Watchdog Timer Fault tolerant operation (212ms).
Power Input 115/220 VAC 50/60 Hz. Only the 115VAC.
Version has been tested to comply with the
Underwriters Laboratories Standards for safety.
Operating Temperature -10 to 40 degrees centigrade.
Options Counting.
Opto-22 relay modules.
12 to 28 volt DC operation.
220 VAC operation.
440HS High speed 100 samples a second.
Analog output module.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Industrial Data Systems IDS 430 and is the answer not in the manual?

Industrial Data Systems IDS 430 Specifications

General IconGeneral
BrandIndustrial Data Systems
ModelIDS 430
CategoryMeasuring Instruments
LanguageEnglish