Parameters 35, 36, 37, and 38: Print Codes
The IDS 430/433 provides 4 programmable print codes. The print codes are used
to send special setup parameters to the printer, such as select print size or select
print font. Each print code is up to 4 characters long. Consult your printer manual
for the print codes that you may want to use. Enter the codes in decimal format
(an ASCII carriage return = 13). Select parameter 35 to begin print code 1 entry.
The IDS 430/433 prompts “C0 XXX” where xxx is the current character 0 print
code value. Enter data for character 0. The IDS 430/433 prompts “C1 XXX”.
Continue the code entry. Enter a 0 to end print code entry.
Parameter 39 Enable TTL Remote Control (1 [enabled])
Use parameter 39 to enable remote control using TTL inputs 1 thru 4 (TB4 pins
10-13).
Enter a 1 to use TTL inputs 1-4 to activate scale basic functions 1 - 4. For
example, grounding TB4 pin 1 (TTL input 1) activates scale basic function 1.
Enter a 0 to disable TTL remote control.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Industrial Data Systems IDS 430 and is the answer not in the manual?

Industrial Data Systems IDS 430 Specifications

General IconGeneral
BrandIndustrial Data Systems
ModelIDS 430
CategoryMeasuring Instruments
LanguageEnglish