IDS 430/433 Users Manual Version 1.0
- 37 -
Parameter 27 TX2 Control / Station ID (255 [single station])
Serial Port 2 can be used for continuous transmission of scale data or as a
network buss or for single station remote control.
• Enter a 0 to enable continuous transmission of TX 2 data. The data sent is
configured in parameter 28 (TX2 Format).
• Enter a station ID (1 to 254) for multi-drop network configuration
• Enter 255 for single station remote control
Parameter 28 TX2 Format (2 Condec format)
Serial Port 2 can be used for continuous transmission of scale data. The TX2
Format parameter determines what is sent. There are 5 selections:
1 - AND: <status>, <mode>, <polarity><weight><units><terminate>
Status: OL (overload), ST (stable), US (unstable, in motion)
Mode: GS (gross mode), NT (net mode)
Polarity: + (positive weight), - (negative weight)
Weight: 7 characters data, NOT zero blanked, with decimal point
Units: lb, kg, t (ton), tn (tonne), g<sp> (gram), oz
Terminate: lf, cr (line feed, carriage return)
2 - CONDEC: <stx><polarity><weight><units><mode>>status><terminate>
Polarity: space (positive weight), - (negative weight)
Weight: 7 characters, zero blanked, with decimal point
Units: L (lb), K (kg), T (ton), G (gram), O (oz)
Mode: G (gross mode), N (net mode)
Status: <space> (valid weight), M (motion), O (over wt), I(invalid)
Terminate: lf, cr (line feed, carriage return)
3 - WEIGHTRONIX: <mode1><mode2><polarity><weight><space><units><term>
Mode1: space (gross mode), 0 (zero if net mode)
Mode2: G (gross mode), N (net mode)
Polarity: + (positive weight), - (negative weight)
Weight: 6 characters, NOT zero blanked, with decimal point
Units: lb, kg, oz, g <space>(gram), t<space> (ton), tn (tonne)
Terminate: lf, cr (line feed, carriage return)
4 - OHAS:
<polarity><weight><space><units><2 spaces><mode><status><term>
Polarity: space (positive weight), - (negative weight)
Weight: 7 digits, zero blanked, with decimal point
Units: lb, kg, oz, g <space>(gram), t<space> (ton), tn (tonne)
Mode: G (gross mode), N (net mode)
Status: <space> (valid weight), M (motion), O (over wt), I(invalid)
Terminate: lf, cr (line feed, carriage return)
5 - Print label 85: transmits the contents of parameter 85 (print label 85)
Data entered into a print label can include register data:
[253] [reg no] buffer register data, minimum size (zero blanked no
spaces)
[254] [reg no] buffer data, 7 character field, zero blanked, right
justified
.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Industrial Data Systems IDS 430 and is the answer not in the manual?

Industrial Data Systems IDS 430 Specifications

General IconGeneral
BrandIndustrial Data Systems
ModelIDS 430
CategoryMeasuring Instruments
LanguageEnglish