Programming the Device
Once you have switched the unit into SSP, open Validator Manager and click detect devices. This will scan all active
com ports for a unit, if your BV30 fails to connect please ensure the correct drivers are installed and the unit is in
SSP.
By selecting the Program tab, you can reprogram the BV30. To begin the upload, click open file, then browse to the
file location (usually Downloads) before clicking OK.
Once the file has been selected its information will be populated and the Program device tab will become active.
Finally hit ‘Program Device’, the unit’s bezel will now begin to flash signalling the update has begun.
When completed the unit will restart and a pop-up box will appear saying Device Programming Complete.
DA3
General Description
The DA3 is a hand-held validator programming system that enables the user to re-program ITL banknote validators
in the field, without the use of a PC. Dataset and firmware files for different validator models can be stored on the
DA3. Once programmed the user can update or override existing software as well as test the functionality of the
validator, away from the host machine.
System Requirements
Windows XP SP3 or above
.Net Framework 4
256mb ram
50mb hard disk free
Connected DA3 with active com port
Device Programming System software (available on ITL Website)
Programming the Device
Open Device Programming System software and add the dataset files you will use.
Interrupting the download process can result in the unit entering a non-functional state, once the process
has started it cannot be halted.