Common Parameter Settings
‑61‑
Param
eter
Code
Commu
nication
Address
Parameter Name Value Default Unit Change
Mode
F0‑35 0xF023 Auxiliary frequency
gain coefficient
source
0: 100%
2: AI1
5: Pulse reference
6: Multi‑reference
7: Simple PLC
8: PID
9: Communication
10: Potentiometer MD‑BP‑M
Others: F connector
0 ‑ Real time
F0‑38 0xF026 Multi‑reference 0
setting mode
0: F0‑39
1: AI1
2: Reserved
3: Potentiometer MD‑BP‑M
4: Pulse reference
5: PID
6: b5‑01/b6‑01 (main frequency digital
setting)
Others: F connector
0 ‑ Real time
F0‑39 0xF027 Multi‑reference 0 ‑800.0% to 800.0% 0.0 % Real time
F0‑40 0xF028 Multi‑reference 1 ‑800.0% to 800.0% 0.0 % Real time
F0‑41 0xF029 Multi‑reference 2 ‑800.0% to 800.0% 0.0 % Real time
F0‑42 0xF02A Multi‑reference 3 ‑800.0% to 800.0% 0.0 % Real time
F0‑45 0xF02D Ramp acceleration/
deceleration mode
0: Linear acceleration/deceleration
1: S‑curve acceleration/deceleration
0 ‑ Real time
F0‑46 0xF02E Ramp acceleration/
deceleration time
base frequency
0: Rated frequency
1: Maximum frequency
2: 100 Hz
3: Set frequency
1 ‑ Real time
F0‑48 0xF030 Ramp 1
acceleration time
0.0s to 6500.0s 20.0 s Real time
F0‑49 0xF031 Ramp 1
deceleration time
0.0s to 6500.0s 20.0 s Real time
F0‑50 0xF032 Ramp 1
acceleration start
arc
0.00s to 650.00s 0.00 s Real time
F0‑51 0xF033 Ramp 1
acceleration end
arc
0.00s to 650.00s 0.00 s Real time
F0‑52 0xF034 Ramp 1
deceleration start
arc
0.00s to 650.00s 0.00 s Real time
F0‑53 0xF035 Ramp 1
deceleration end
arc
0.00s to 650.00s 0.00 s Real time