Common Parameter Settings
‑63‑
Param
eter
Code
Commu
nication
Address
Parameter Name Value Default Unit Change
Mode
F1‑22 0xF116 Asynchronous
motor rotor
resistance
0.001 Ω to 65.535 Ω 0.908 Ω Real time
F1‑24 0xF118 Leakage
inductance of
asynchronous
motor stator
0.01 mH to 655.35 mH 5.28 mH Real time
F1‑26 0xF11A Leakage
inductance of
asynchronous
motor rotor
0.01 mH to 655.35 mH 5.28 mH Real time
F1‑28 0xF11C Asynchronous
motor mutual
inductance
0.1 mH to 6553.5 mH 156.8 mH Real time
F1‑30 0xF11E No‑load current of
asynchronous
motor
0.01 A to 655.35 A 4.20 A Real time
F1‑32 0xF120 D axis inductance
of synchronous
motor
0.01 mH to 655.35 mH 5.28 mH Real time
F1‑34 0xF122 Axis Q inductance
of synchronous
motor
0.01 mH to 655.35 mH 5.28 mH Real time
F1‑69 0xF145 Auto‑tuning
selection
0: No auto‑tuning
1: Partial static auto‑tuning of
asynchronous motor
2: Dynamic auto‑tuning of asynchronous
motor
3: Complete static auto‑tuning of
asynchronous motor
5: Dead zone auto‑tuning
14: UV gain difference auto‑tuning
0 ‑ At stop
F2‑14 0xF20E Motor running
direction selection
0: Same as the set direction
1: Opposite to the set direction
0 ‑ At stop
F2‑15 0xF20F Start mode 0: Direct start
1: Flying start
0 ‑ Real time
F2‑16 0xF210 Flying start mode 0: Start from the frequency at stop
1: Start from the mains frequency
2: Start from the maximum frequency
4: Magnetic field directional flying start
4 ‑ Real time
F2‑17 0xF211 ON_OFF1 (start/
stop)
0: Decelerate to stop
1: Coast to stop
2: Stop at maximum capability
0 ‑ Real time