Selection of Options
‑111‑
Table 4–13 Mounting dimensions of 4–17 A AC output reactors (unit: mm)
Series A B C D E F G
4 and 7.8 A 100 Max. 60 Max. 115 56 34 4.8×9 2.5 mm
2
10 A 100 Max. 70 Max. 115 56 43 4.8×9 2.5 mm
2
14 A 125 Max. 70 Max. 135 100 45 5×8 2.5 mm
2
17 A 125 Max. 75 Max. 135 100 55 5×8 2.5 mm
2
32 A 155 Max. 95 Max. 170 130 56 85×12 2.5 mm
2
4.1.6 Magnetic Ring and Buckle
Model
The magnetic ring is mainly used on the input side or output side of the AC drive.
Install it as close to the drive as possible. When it is installed on the input side, the
noise in the input power supply system of the drive can be suppressed. When it is
installed on the output side, the interference generated by the drive to external
devices can be suppressed and the bearing current can be lowered.
The magnetic ring or buckle can also be used to suppress the leakage current or other
signal cable interference in some applications.
● Amorphous magnetic ring: high permeability when within 1 MHz, good
suppression of drive interference, but high cost
● Ferrite magnetic buckle: good performance when in the frequency band above 1
MHz, suppression of interference noise of various signal cables, low cost, and
convenient and neat for installation
Table 4–14 Appearance and models of the magnetic rings and buckle
Category
Model
Appearance
Magnetic ring
DY644020H
DY805020H
DY1207030H
Magnetic buckle
DYR‑130‑B