PROFINET Communication
‑69‑
The setting takes effect after power‑on again.
● Communication timeout
You can use this parameter to set the PN communication timeout period. After the
setting takes effect, the communication network stops running when the timeout
period expires.
Para. No.
Description
Fd‑55
This parameter defines the PN communication timeout time in ms.
The setting takes effect after power‑on again.
4.7 Communication Configuration
4.7.1 Configuration
To use a PROFINET master station, you must configure the GSDML file of the slave
station first to add the slave station devices to the master station system. If the slave
station devices have been added to the master station system, skip this step. Contact
Inovance agents or vendors to get the GSDML file.
If the 200 SMART ST&SR series master station is used, the PLC firmware version must
be 2.05 or later.
The configuration procedure is as follows:
1. Create a project
a. Select "Create new project", set a project name and storage path in the "Project
name" and "Path" fields, and then click "Create".
b. Select "Configure a device", as shown below.