6 Parameter Description
-
206
-
Function
Code
Name Setting Range Default Unit Property
F5-33 F5-33 Program control selection 0 to 65535 0 -
F5-33 is used to select the elevator functions.
󶍾-
ed by this bit is enabled; if this bit is set to 0, the function is disabled.
󶍾
F5-33 Terminal program control
Bit Function Description Default
Bit3
󶍾
requirement for Hong
Kong
󶍾
F6-44 applying to Hong Kong become enabled
automatically.
0
Bit4
Arrival gong disabled
at night
The arrival gong is disabled from 22:00 p.m. to
7:00 a.m.
0
Bit6
Door lock disconnected
at inspection switched
over to normal running
The door lock is additionally disconnected
once when the inspection state is switched
over to the normal running state.
0
Bit7
Fault code not
displayed on the
keypad
The keypad does not blink to display the fault
code.
0
Bit8
Door open command
canceled immediately
at door open limit
The system immediately cancels the door open
command after receiving the door open limit.
0
Bit9
Car stop and zero-
speed torque holding
at abnormal brake
feedback
When the brake feedback is abnormal, the
elevator arrives at the door-zone position and
stops. The door keeps closed, and the system
holds torque output as long as possible. After
the system is overloaded, there is no torque
output, and the elevator may fall in this case.
Be cautious of using this function.
0
Function
Code
Name Setting Range Default Unit Property
F5-34
Terminal state
display
Monitoring of I/O terminals
on MCB
- -
F5-35
Terminal state
display
Monitoring of I/O terminals
on CTB, CCB and HCB
- -
These parameters are used to monitor the state of all I/O terminals of the system.
󶍾󶍾
A
B
C
D
E
F
G
DP
A
B
C
D
E
F
G
DP
A
B
C
D
E
F
G
DP
A
B
C
D
E
F
G
DP
5
4 3
2
A
B
C
D
E
F
G
DP
1
󶙽Monitoring of all I/O terminals