6 Parameter Description
-
207
-
F5-34 Terminal state display
1 2 3 4 5
A -
Inspection
signal
Up slow-down 1
signal
Door machine 1
light curtain
Reserved
B
Up leveling
signal
Inspection up
signal
Down slow-down
1 signal
Door machine 2
light curtain
RUN contactor
output
C
Down leveling
signal
Inspection
down signal
Up slow-down 2
signal
Brake contactor
feedback 2
Brake contactor
output
D
Door zone
signal
Fire
emergency
signal
Down slow-down
2 signal
UPS input
Shorting door lock
circuit contactor
control
E
Safety circuit
feedback 1
Up limit signal
Up slow-down 3
signal
Elevator lock
input
Fire emergency
F
Door lock
circuit
feedback 1
Down limit
signal
Down slow-down
3 signal
Safety circuit
feedback 2
-
G
RUN contactor
feedback
Overload
signal
Shorting door
lock circuit
contactor
feedback
Shorting PMSM
stator contactor
feedback
-
DP
Brake contactor
feedback 1
Full-load
signal
running signal
Door lock
circuit
feedback 2
-
F5-35 Terminal state display
1 2 3 4 5
A
Door 1 light
curtain
Door open
button
Door 1 open
output
Door open
button display
System light
curtain state 1
B
Door 2 light
curtain
Door close
button
Door 1 close
output
Door close
button display
System light
curtain state 2
C
Door 1 open
limit
Door open
delay button
Door lock signal
Door open
delay button
display
Hall call elevator
lock input
D
Door 2 open
limit
Direct travel
ride signal
Door 2 open
output
Non-door zone
stop output
emergency input
E
Door 1 close
limit
Attendant
signal
Door 2 close
output
Reserved Full-load signal
F
Door 2 close
limit
Direction
change signal
Door lock signal Buzzer output Overload signal
G Full-load signal
Independent
running signal
Up arrival gong Reserved -
DP
Overload
signal
operation
signal
Down arrival
gong
Energy saving
sign
-
Function
Code
Name Setting Range Default Unit Property
F5-36 Load cell input selection 0 to 3 1 -
★
It is used to set the channel of setting the elevator load cell signal. When a load cell