6 Parameter Description
-
220
-
Function
Code
Name Setting Range Default Unit Property
F6-43
Attendant function
selection
0 to 65535 128 -
★
F6-43 is used to select the attendant-related elevator functions. Each bit of the
is enabled; if this bit is set to 0, the function is disabled. You can view and set this
function code using the bits.
F6-43 Attendant function selection
Bit Function Description Default
Bit0
Calls canceled after
entering attendant
state
All calls are canceled after the elevator enters
0
Bit1
Not responding to
hall calls
The car blinks inside, prompting there is a hall call,
but the system does not respond.
0
Bit2
Attendant/
Automatic
switchover
If this function is enabled, the setting of F5-00 is valid 0
Bit3
Door close at
jogging
The elevator door closes after the attendant presses
the door close button manually.
0
Bit4
Automatic door
close
It is the same as the normal state. After the door
open holding time is reached, the door closes
automatically.
0
Bit5
Buzzer tweeting
at intervals in
attendant state
When there is a registered hall call, the buzzer tweets
2.5s at intervals.
0
Bit6
Continuous
buzzer tweeting in
attendant state
When there is a registered hall call, the
buzzer tweets continuously until there is a registered
0
Bit7
Car call button
blinking to prompt
When the hall call input is active, the car call button
1
Function
Code
Name Setting Range Default Unit Property
F6-44
Fire emergency function
selection
0 to 65535 16456 -
★
if this bit is set to 0, the function is disabled.