6 Parameter Description
-
221
-
F6-44 Fire emergency function selection
Bit Function Description Default
Bit0 to
Bit2
Reserved - -
Bit3
Arrival gong output
emergency state
The arrival gong is output in the inspection
1
Bit4
Multiple car calls
emergency state
emergency state. If this function is disabled,
only one car call can be registered.
0
Bit5
Retentive at power failure
system and car state will be memorized
at power failure and be resumed after the
system is powered on again.
0
Bit6
Closing door by holding
down the door close
button
process can be completed only by holding
down the door close button until the door
close limit is reached. Otherwise, it will be
switched over to door open automatically.
1
Bit7 Reserved - -
Bit8
Door close at car call
registering
The elevator enters the door close process
automatically if a car call is registered.
0
Bit9
emergency state
state.
0
Bit10
input.
JP22 input switch and the door close button
are enabled simultaneously, the buzzer
tweets and the system outputs the door close
signal. If the door lock is not enabled within
10s, the system outputs the shorting door
lock circuit contactor signal, and the elevator
starts running (used together with SCB-A).
0
Bit11
0
Bit12
Not clearing car calls
at reverse door open in
that have been registered are not cleared at
reverse door open.
0
Bit13 Reserved - -
Bit14
Opening door by holding
down the door open
button
process can be completed only by holding
down the door open button until the door
open limit is reached. Otherwise, it will be
switched over to door close automatically.
1
Bit15
Automatic door open at
The door opens automatically after the
0