6 Parameter Description
-
255
-
󶍾
FE-32 Elevator function selection 1
Bit Function Description Default
Bit0 Reserved - 0
Bit1 Reserved - 0
Bit2
Re-leveling
function
The elevator performs re-leveling at a low speed
with door open. An external shorting door lock
circuit contactor needs to be used together.
0
Bit3
Door pre-open
function
During normal stop, when the elevator speed is
smaller than a certain value and the door zone
signal is active, the system shorts the door lock by
means of the shorting door lock circuit contactor
and outputs the door open signal, implementing
door pre-open. This improves the elevator use
󶎀
0
Bit4
Stuck hall call
cancellation
󶍾
hall call buttons. If the state is abnormal, the system
cancels the stuck hall call.
0
Bit5
󶍿
function
From 10:00 p.m to 6:00 a.m., the elevator runs to the
󶍿󶍾
󶍿
0
Bit6
Down collective
selective peak
service
The peak service at down collective selective is
used.
0
Bit7
Parallel/Group
control peak
service
The peak service is used. 0
Bit8
Time-based service
󶍿
For details, see the description of related parameters
in group F6.
0
Bit9 VIP function The VIP function is used. 0
Bit10 Reserved - 0
Bit11 Car call deletion
A call can be deleted by pressing the button twice
consecutively.
1
Bit12 Hall call deletion 0
Bit13
to
Bit15
Reserved - 0
Function
Code
Name Setting Range
Default
Unit Property
FE-33 Elevator function selection 2 0 to 65535 36 -
󶍾-
ed by this bit is enabled; if this bit is set to 0, the function is disabled.
󶍾